A cable is usually a rope-like cable made by twisting several or several sets of wires (at least two in each group). Each set of wires is insulated from each other and often twists around a center. The entire bread has a height. Insulation coating. They are set up in the air or installed underground and under water for telecommunications or power transmission. Cables can be divided into power cables, communication cables, and control cables according to their use. So when the cable is used, is there any security requirement? What is its protection measure? How to store it? The details are as follows:
Safety requirements
1. When the cables cross each other, the high voltage cable should be under the low voltage cable. If one of the cables is protected by a pipe within 1m before and after the intersection or separated by a partition, the minimum allowable distance is 0.25m.
Safety protection measures when using wire and cable
2. When the cable is approaching or intersecting with the heat pipe, the minimum distance between parallel and crossover is 0.5m and 0.25m, respectively, if there is thermal insulation measures.
3. Pipes should be protected when they intersect with railways or roads. Protection pipes should extend beyond the track or road 2m away.
4. The distance between the cable and the building foundation should ensure that the cable is buried outside the building's loose water; when the cable is introduced into the building, the pipe should be protected and the protection pipe should be beyond the building's loose water.
5. The distance between the cable directly buried in the ground and the grounding of the general grounding device shall be 0.25~0.5m; the buried depth of the cable directly buried in the ground shall not be less than 0.7m, and shall be buried under the frozen soil.
Safety protection measures when using wire and cable
Safeguard
With the rapid development of the buried construction of power cables, the higher requirements for cable protection, the cable protection sleeve is made of polyethylene PE and high-quality steel pipe after sandblasting, blasting or coating, and heat curing. Process made. It is an electrical insulation tube that is most commonly used to protect wires and cables. Because it has good insulation properties, high chemical stability, no rust, no aging, can adapt to harsh environments and is widely used.
The use of cable protection sleeves to protect the cable can achieve the following advantages:
1, good corrosion resistance, long life, can be used in the wet saline-alkaline zone.
2, flame retardant, heat resistance, can be used under 130 degrees of high temperature without deformation, in case of fire does not burn.
3, high strength and high rigidity. Used directly under the carriageway without the need for additional concrete protection, can roll the construction progress of the cable project.
4. Cable protection sleeves, whether they are pipes or fittings, have a certain degree of flexibility, which can withstand the damage caused by external heavy pressure and foundation settlement.
5, has a good anti-interference signal performance.
6. The inner wall is smooth and does not scratch the cable. The design adopts socket-type connection to facilitate the installation and connection. The rubber sealing ring seal at the joint not only adapts to thermal expansion and contraction, but also prevents mud sand from entering.
Storage method
If the cable is to be stored for a long period of time, the following considerations should be taken, depending on where the cable is placed:
1, under the roof. Cables can only be used if they are not directly exposed to sunlight or ultra-high temperatures. Standard LAN cables can be used. Pipes are recommended.
2, on the outside wall. Avoid direct sunlight on the wall and human damage.
3, in the pipeline (plastic or metal). If in the pipe, pay attention to the damage of the plastic pipe and the heat conduction of the metal pipe.
4, suspended applications / overhead cables. Consider the sagging and pressure of the cable, which kind of binding method you intend to use, and whether the cable is exposed to direct sunlight.
5, laid directly in the underground cable trench, this environment is the smallest control range. The installation of cable trenches should be regularly checked for dryness or moisture level.
6, underground pipelines. In order to facilitate future upgrades, cable replacement and isolation from surface pressure and surrounding environment, auxiliary pipelines are isolated, and auxiliary piping is a better method. But don't expect the pipeline to stay dry forever, which will affect the choice of cable types.
Henan sanheng industrial co., LTD., founded in 2000, It is one of the top wire and cable manufacturers in China's wire and cable industry for nearly 20 years. the company has more than 5 production lines.
The production cable can be divided into more than 50 varieties and subdivided into 1000 specifications.All products have passed national certification, such as China compulsory certification, bv certification, Nigerian SONCAP certificate, China national industrial certification, etc. China national industrial production license, etc.It also has the ability to produce products that meet international standards, such as iec, ce, rohs, etc.
If you want to buy wires and cables, you can ask the customer service staff and we will get back to you as soon as possible.
-

600-1000V CU XLPE Power Cable
Conductor:Bare Copper Conductor of Class 1/2 (Solid)
Insulation:XLPE Compound
Insulation Color:Red, Blue, Grey, Yellow/Green or as request
-

600-1000V AL XLPE Power Cable
3500 V:Bare Aluminum Conductor of Class 1/2 (Solid)
Insulation:XLPE Compound
Insulation Color:Red, Blue, Grey, Yellow/Green or as request
-

600-1000V Flexible Power Cable
Conductor:Bare Copper Conductor of Class 5 (Flexible)
Insulation:PVC Compound
Insulation Color:Red, Blue, Grey, Yellow/Green or as request
-

600-1000V SWA Armoured Cable
Conductor:Bare Copper Conductor of Class 1/2 (Solid)
Insulation:XLPE Compound
Insulation Color:Red, Blue, Grey, Yellow/Green or as request